Evaluation of measurement uncertainty for thermometers with calibration equations
3 references·4 citing·20 second hop
Evaluation of measurement uncertainty for thermometers with calibration equations (2006)Evaluation of measurement uncertainty for…GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT (2006)GUIDE TO THE EXPRESSION OF UN…Inverse vs. classical calibration for small data sets (2000)Inverse vs. classical calibra…Inverse calibration predicts better than classical calibration (1998)Inverse calibration predicts …Determination of Optimal Measurement Points for Calibration Equations—Examples by RH Sensors (2019)Determination of Optimal Meas…Uncertainty propagation in the calibration equations for NTC thermistors (2018)Uncertainty propagation in th…Uncertainty Analysis in Humidity Measurements by the Psychrometer Method (2017)Uncertainty Analysis in Humid…The effect of calibration equations on the uncertainty of UV–Vis spectrophotometric measurements (2010)The effect of calibration equ…Evaluation of measurement uncertainty for analytical procedures using a linear calibration function (2002)Handbook for Calculation of Measurement Uncertainty in Environmental Laboratories (2003)Uncertainty sources in UV-Vis spectrophotometric measurement (2006)Measuring Uncertainty Using Different Approaches: A Case Study for Acetaminophen Quantification (2016)Compromise in uncertainty estimation by modelling and validation approaches for an HPLC-UV method for measurement of biochemical indicators of vitamins A and E (2018)Application of Measurement Uncertainty on Conformity Assessment in Pharmaceutical Drug Products (2020)Uncertainty evaluation of humidity sensors calibrated by saturated salt solutions (2006)Industrial Moisture and Humidity Measurement (2013)Propagation of uncertainty for non-linear calibration equations with an application in radiation thermometry (2003)The propagation of uncertainty with calibration equations (2007)Optimum choice of measurement points for sensor calibration (1996)Simple algorithms for nonlinear calibration by the classical and standard additions methods (2005)Coordinate Swapping in Standard Addition Graphs for Analytical Chemistry: A Simplified Path for Uncertainty Calculation in Linear and Nonlinear Plots (2014)On the development of quality assurance (2014)Uncertainty in photometric analysis: a case study (2005)Assessment of quality performance parameters for straight line calibration curves related to the spread of the abscissa values around their mean (2006)Uncertainty analysis of polymer-based capacitive relative humidity sensor at negative temperatures and low humidity levels (2023)Guidelines and recommended terms for expression of stable‐isotope‐ratio and gas‐ratio measurement results (2011)CODATA recommended values of the fundamental physical constants: 2010 (2012)Quantifying Uncertainty in Analytical Measurement (2012)
this work references cited by second hop

References

  • 2006GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT6,460 cited
  • 2000Inverse vs. classical calibration for small data sets61 cited
  • 1998Inverse calibration predicts better than classical calibration44 cited

Cited by

  • 2017Uncertainty Analysis in Humidity Measurements by the Psychrometer Method31 cited
  • 2010The effect of calibration equations on the uncertainty of UV–Vis spectrophotometric measurements27 cited
  • 2018Uncertainty propagation in the calibration equations for NTC thermistors20 cited
  • 2019Determination of Optimal Measurement Points for Calibration Equations—Examples by RH Sensors12 cited

Only edges whose both ends are imported exist here. Widen the year window, or show the whole map. Back to the work