SZodixStudyAcademic Library
ShelvesOpen access
Study · an open academic library·Metadata from OpenAlex (CC0)·Shelves·OpenAlex metadata, de-duplicated
Accurate analytical measurements in the atomic force microscope: a microfabricated spring constant standard potentially traceable to the SI
1 references·16 citing·29 second hop
Accurate analytical measurements in the atomic force microscope: a microfabricated spring constant standard potentially traceable to the SI (2003)Accurate analytical measurements in the a…A Realization of the SI Watt by the NPL Moving-coil Balance (1990)A Realization of the SI Watt …Comparing AFM cantilever stiffness measured using the thermal vibration and the improved thermal vibration methods with that of an SI traceable method based on MEMS (2017)Comparing AFM cantilever stif…SI-traceable determination of the spring constant of a soft cantilever using the nanonewton force facility based on electrostatic methods (2016)SI-traceable determination of…The multi-position calibration of the stiffness for atomic-force microscope cantilevers based on vibration (2015)The multi-position calibratio…A metrological approach for the calibration of force transducers with interferometric readout (2015)A metrological approach for t…Measurement of cantilever spring constant using an electrostatic sensing and actuating force measurement system (2014)Measurement of cantilever spr…Report on the first international comparison of small force facilities: a pilot study at the micronewton level (2011)Report on the first internati…SI traceability: Current status and future trends for forces below 10 microNewtons (2009)SI traceability: Current stat…Improved methods and uncertainty analysis in the calibration of the spring constant of an atomic force microscope cantilever using static experimental methods (2009)Improved methods and uncertai…A new facility to realize a nanonewton force standard based on electrostatic methods (2009)A new facility to realize a n…SI-traceable determination of spring constants of various atomic force microscope cantilevers with a small uncertainty of 1% (2007)SI-traceable determination of…Microforce materials tester based on the levitation mass method (2007)Microforce materials tester b…SI-Traceable Spring Constant Calibration of Microfabricated Cantilevers for Small Force Measurement (2006)SI-Traceable Spring Constant …Atomic force microscope cantilever calibration device for quantified force metrology at micro- or nano-scale regime: the nano force calibrator (NFC) (2006)Atomic force microscope canti…Microforce materials tester (2005)Microforce materials testerMethod for generating and measuring the micro-Newton level forces (2005)Method for generating and mea…Force calibration of stylus instruments using silicon microcantilevers (2005)Force calibration of stylus i…A new precise determination of Newton's gravitational constant (1995)Review of SI traceable force metrology for instrumented indentation and atomic force microscopy (2005)Prototype cantilevers for SI-traceable nanonewton force calibration (2006)Improving environmental noise suppression for micronewton force sensing based on electrostatic by injecting air damping (2014)Comparison of electrostatic and photon pressure force references at the nanonewton level (2018)Accurate Measurement of the Planck Constant (1998)An initial measurement of Planck's constant using the NPL Mark II watt balance (2007)A force measurement system based on an electrostatic sensing and actuating technique for calibrating force in a micronewton range with a resolution of nanonewton scale (2011)High-precision horizontally directed force measurements for high dead loads based on a differential electromagnetic force compensation system (2016)Current state of the art in small mass and force metrology within the International System of Units (2018)Tables of Physical and Chemical Constants (1936)Precision measurement and fundamental constants (1971)The 1986 adjustment of the fundamental physical constants (1987)Towards an electronic kilogram: an improved measurement of the Planck constant and electron mass (2005)CODATA recommended values of the fundamental physical constants: 2006 (2008)Guide to the Expression of Uncertainty in Measurement (1995)Accurate Calibration and Uncertainty Estimation of the Normal Spring Constant of Various AFM Cantilevers (2015)Progress toward Système International d'Unités traceable force metrology for nanomechanics (2004)GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT (2006)Investigation of the comparison method for the dynamic calibration of force transducers (1998)Proposal for a step response evaluation method for force transducers (2003)Measurement of the electrical and mechanical responses of a force transducer against impact forces (2006)Toward dynamic force calibration (2009)Toward Establishing Dynamic Calibration Method for Force Transducers (2009)Introduction to Error Analysis (2009)Traceable measurements of small forces and local mechanical properties (2011)Proficiency tests for laboratories: a systematic review (2014)Impact response measurement of an accelerometer (2006)Method of generating and measuring static small force using down-slope component of gravity (2007)
this work references cited by second hop

References

  • 1990A Realization of the SI Watt by the NPL Moving-coil Balance166 cited

Cited by

  • 2011Report on the first international comparison of small force facilities: a pilot study at the micronewton level67 cited
  • 2009SI traceability: Current status and future trends for forces below 10 microNewtons55 cited
  • 2006Atomic force microscope cantilever calibration device for quantified force metrology at micro- or nano-scale regime: the nano force calibrator (NFC)53 cited
  • 2009Improved methods and uncertainty analysis in the calibration of the spring constant of an atomic force microscope cantilever using static experimental methods51 cited
  • 2007SI-traceable determination of spring constants of various atomic force microscope cantilevers with a small uncertainty of 1%47 cited
  • 2005Microforce materials tester46 cited
  • 2009A new facility to realize a nanonewton force standard based on electrostatic methods45 cited
  • 2005Method for generating and measuring the micro-Newton level forces35 cited
  • 2005Force calibration of stylus instruments using silicon microcantilevers25 cited
  • 2015A metrological approach for the calibration of force transducers with interferometric readout23 cited
  • 2017Comparing AFM cantilever stiffness measured using the thermal vibration and the improved thermal vibration methods with that of an SI traceable method based on MEMS23 cited
  • 2015The multi-position calibration of the stiffness for atomic-force microscope cantilevers based on vibration

Only edges whose both ends are imported exist here. Widen the year window, or show the whole map. Back to the work

21 cited
  • 2016SI-traceable determination of the spring constant of a soft cantilever using the nanonewton force facility based on electrostatic methods19 cited
  • 2007Microforce materials tester based on the levitation mass method19 cited
  • 2014Measurement of cantilever spring constant using an electrostatic sensing and actuating force measurement system18 cited
  • 2006SI-Traceable Spring Constant Calibration of Microfabricated Cantilevers for Small Force Measurement18 cited