Ten normal donors were monitored before, during, and after ten weekly donations of platelet concentrates prepared using the Haemonetics Model 30 blood processor. Analysis of these data indicates about a 20 per cent decrease of lymphocytes, with B cells being significantly decreased in half of these patients. While coincident immunoglobulin deficiencies did not develop in this short-term study, it is presumed that these would occur with a prolongation of platelet donations, as has been noted in previous studies. Additional studies are indicated to further delineate the lymphocyte depletion in normal platelet donors.