SZodixStudyAcademic Library
ShelvesOpen access
Study · an open academic library·Metadata from OpenAlex (CC0)·Shelves·OpenAlex metadata, de-duplicated
Reliability of Goniometric Measurements and Visual Estimates of Knee Range of Motion Obtained in a Clinical Setting
3 references·14 citing·35 second hop
Reliability of Goniometric Measurements and Visual Estimates of Knee Range of Motion Obtained in a Clinical Setting (1991)Reliability of Goniometric Measurements a…Intraclass correlations: Uses in assessing rater reliability. (1979)Intraclass correlations: Uses…ON THE METHODS AND THEORY OF RELIABILITY (1976)ON THE METHODS AND THEORY OF …Foundations of Behavioral Research (1974)Foundations of Behavioral Res…Measurement of knee joint range of motion with a digital goniometer: A reliability study (2018)Measurement of knee joint ran…Inter-rater and intra-rater reliability of the fluid goniometer for measuring active knee flexion in painful knees; correlations do not mean agreement (2017)Inter-rater and intra-rater r…How Does Level and Type of Experience Affect Measurement of Joint Range of Motion? (2017)How Does Level and Type of Ex…Reliability and concurrent validity of knee angle measurement: Smart phone app versus universal goniometer used by experienced and novice clinicians (2014)Reliability and concurrent va…Confiabilidade intra e interexaminadores e erro da medição no uso do goniômetro e inclinômetro digital (2012)Confiabilidade intra e intere…Validity and reliability of using photography for measuring knee range of motion: a methodological study (2011)Validity and reliability of u…Knee range of motion: reliability and agreement of 3 measurement methods. (2011)Knee range of motion: reliabi…Inter-rater reliability for measurement of passive physiological movements in lower extremity joints is generally low: a systematic review (2010)Inter-rater reliability for m…Is visual estimation of passive range of motion in the pediatric lower limb valid and reliable (2009)Is visual estimation of passi…Digital goniometric measurement of knee joint motion. Evaluation of usefulness for research settings and clinical practice (2007)Digital goniometric measureme…A study of the noninstrumented physical examination of the knee found high observer variability (2006)A study of the noninstrumente…Factors Affecting Interpretation of Reliability Coefficients (2004)Factors Affecting Interpretat…Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions (2001)Intra- and intertester reliab…Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects (1997)Intratester and intertester r…Akufo and Ibarapa (1965)The Measurement of Observer Agreement for Categorical Data (1977)STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT (1986)The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature (2018)Clinical Measurement of Range of Motion (1987)Health Measurement Scales: A Practical Guide to Their Development and Use (1989)Health Measurement Scales--A Practical Guide to Their Development and Use (2010)What makes a measurement instrument valid and reliable? (2010)Accuracy and reliability of knee goniometry methods (2018)Reliability of Goniometric Measurements (1978)Statistical Methodology for the Concurrent Assessment of Interrater and Intrarater Reliability: Using Goniometric Measurements as an Example (1994)A Concordance Correlation Coefficient to Evaluate Reproducibility (1989)Smartphone goniometer has excellent reliability between novice and experienced physical therapists in assessing knee range of motion (2020)The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews (2003)A Practical Guide to Research: Design, Execution, and Publication (2011)Reliability and Validity of a Novel Wearable Device for Measuring Elbow Strength (2020)Coefficient Alpha and the Internal Structure of Tests (1951)Statistical principles in experimental design. (1962)Statistical Theories of Mental Test Scores (1969)Assessing the quality of reports of randomized clinical trials: Is blinding necessary? (1996)The job demands-resources model of burnout. (2001)A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research (2016)Sample size requirements for reliability studies (1987)Comparing methods of measurement: why plotting difference against standard method is misleading (1995)Smallest real difference, a link between reproducibility and responsiveness (2001)Intra-rater and Inter-instrument Reliability on Range of Movement of Active Knee Extension (2017)Reliability: What is it, and how is it measured? (2000)Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed (2011)Analysis of the concurrent validity and reliability of five common clinical goniometric devices (2023)The Yale-Brown Obsessive Compulsive Scale (1989)The Yale-Brown Obsessive Compulsive Scale (1989)Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology. (1994)Teacher efficacy: capturing an elusive construct (2001)Validation Guidelines for IS Positivist Research (2004)The Delphi Technique: Making Sense of Consensus (2020)
this work references cited by second hop

References

  • 1979Intraclass correlations: Uses in assessing rater reliability.23,882 cited
  • 1974Foundations of Behavioral Research7,346 cited
  • 1976ON THE METHODS AND THEORY OF RELIABILITY1,310 cited

Cited by

  • 2001Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions254 cited
  • 2014Reliability and concurrent validity of knee angle measurement: Smart phone app versus universal goniometer used by experienced and novice clinicians194 cited
  • 1997Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects152 cited
  • 2010Inter-rater reliability for measurement of passive physiological movements in lower extremity joints is generally low: a systematic review95 cited
  • 2011Validity and reliability of using photography for measuring knee range of motion: a methodological study75 cited
  • 2007Digital goniometric measurement of knee joint motion. Evaluation of usefulness for research settings and clinical practice53 cited
  • 2018Measurement of knee joint range of motion with a digital goniometer: A reliability study47 cited
  • 2012Confiabilidade intra e interexaminadores e erro da medição no uso do goniômetro e inclinômetro digital45 cited
  • 2011Knee range of motion: reliability and agreement of 3 measurement methods.39 cited

Only edges whose both ends are imported exist here. Widen the year window, or show the whole map. Back to the work

2006
A study of the noninstrumented physical examination of the knee found high observer variability
34 cited
  • 2009Is visual estimation of passive range of motion in the pediatric lower limb valid and reliable28 cited
  • 2004Factors Affecting Interpretation of Reliability Coefficients28 cited
  • 2017How Does Level and Type of Experience Affect Measurement of Joint Range of Motion?14 cited
  • 2017Inter-rater and intra-rater reliability of the fluid goniometer for measuring active knee flexion in painful knees; correlations do not mean agreement13 cited