Two-stage flow-dividing system for the calibration of vacuum gauges
5 references·3 citing·22 second hop
Two-stage flow-dividing system for the calibration of vacuum gauges (2007)Two-stage flow-dividing system for the ca…Measurement uncertainties for vacuum standards at Korea Research Institute of Standards and Science (2006)Measurement uncertainties for…Comparison of some metrological characteristics of hot and cold cathode ionisation gauges (2003)Comparison of some metrologic…New, fully automated, primary standard for generating vacuum pressures between 10 10Pa and 3 10 2Pa with respect to residual pressure (1999)New, fully automated, primary…The National Bureau of Standards primary high-vacuum standard (1988)The National Bureau of Standa…Primary pressure measurements down to 10−6 Pa (1988)Primary pressure measurements…A UHV standard with option to be used as partial pressure standard (2020)A UHV standard with option to…Calibration of ultrahigh vacuum gauge from 10−9 Pa to 10−5 Pa by the two-stage flow-dividing system (2011)Calibration of ultrahigh vacu…Stability tests of ionization gauges using two-stage flow-dividing system (2009)Stability tests of ionization…The calibration of vacuum gauges (1977)Gas flowrate measurements for leak calibration (1995)The new UME primary standard for pressure generation in the range from 9 × 10 4 Pa to 103 Pa (2004)Uncertainty evaluation of the IMGC-CNR static expansion system (2004)Reliability of high vacuum measurements (1983)Sensitivity of hot cathode ionization gages (1985)Stable and reproducible Bayard–Alpert ionization gauge (1994)Development of a design for an ionisation vacuum gauge suitable as a reference standard (2020)Long term behaviour of ionization gauges (1981)Long-term stability of two types of hot cathode ionization gauges (1985)Remarks concerning about the characteristics of the extractor vacuum gauge and the Quadrupole Mass Spectrometer (2018)Ultrasonic manometers for low and medium vacua under development at the National Bureau of Standards (1977)GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT (2006)Final report on key comparison APMP.M.P-K3: Absolute pressure measurements in gas from 3 × 10−6Pa to 9 × 10−4Pa (2011)The development of vacuum measurements down to extremely high vacuum – XHV (2012)Revision of the ‘ Guide to the Expression of Uncertainty in Measurement ’. Why and how (2014)Development of a new UHV/XHV pressure standard (cold atom vacuum standard) (2017)NIST calibration services users guide 1998 (1998)New approach to corrections for thermal transpiration effects in capacitance diaphragm gauges (1999)Review Article: Quantum-based vacuum metrology at the National Institute of Standards and Technology (2018)A new fully automated gas flowmeter at the PTB for flow rates between 10-13mol/s and 10-6mol/s (2002)Primary vacuometer based on an ultracold gas in a shallow optical dipole trap (2016)
this work references cited by second hop

References

  • 1999New, fully automated, primary standard for generating vacuum pressures between 10 10Pa and 3 10 2Pa with respect to residual pressure57 cited
  • 1988The National Bureau of Standards primary high-vacuum standard46 cited
  • 1988Primary pressure measurements down to 10−6 Pa34 cited
  • 2003Comparison of some metrological characteristics of hot and cold cathode ionisation gauges29 cited
  • 2006Measurement uncertainties for vacuum standards at Korea Research Institute of Standards and Science21 cited

Cited by

  • 2011Calibration of ultrahigh vacuum gauge from 10−9 Pa to 10−5 Pa by the two-stage flow-dividing system13 cited
  • 2009Stability tests of ionization gauges using two-stage flow-dividing system12 cited
  • 2020A UHV standard with option to be used as partial pressure standard8 cited